What should a technician do if the refrigerant recovery cylinder suspected to be contaminated?

If the recovery cylinder is suspected of being contaminated, a pressure reading of it should be taken and compared to a pressure temperature chart. Recovery cylinders are used for refilling.

Show

Why should the technician watch for signs of contamination in the oil when recovering refrigerant from a system that experienced a compressor burn out?

When recovering refrigerant from a system that experienced a compressor burn-out, watch for signs of contamination in the oil. After recovering refrigerant, if nitrogen is used to flush debris out of the system the nitrogen may be legally vented.

What must be done to the refrigerant that is vented off the top when filling a charging cylinder?

The refrigerant vapor that is vented off the top of the cylinder must be recovered. If after installing a fitting for the purpose of recovering the appliances refrigerant, you find that the system pressure is 0 psig; Recovery is not required.

How should a refrigerant recovery cylinder be labeled?

Recovery cylinders and drums must be painted gray with the shoulder portion painted yellow, per DOT regulations. Label cylinders and drums with a 4- by 4-in. green, nonflammable gas label. Label your cylinders with the type of refrigerant recovered.

Moisture can be removed from a refrigeration system by applying a vacuum. POEs hold moisture more tightly than mineral oil. But in the case of R-134a, the refrigerant effectively competes with the ester lubricant in partitioning the water (i.e., the water moves from the lubricant to the refrigerant).

What may be done to speed the recovery process?

What may be done to speed the recovery process and ensure that all CFC, HCFC, or HFC refrigerant has been removed from a frost-free refrigerator? Turn on the defrost heater to increase the refrigerant’s temperature and vaporize any liquid.

Which of the following refrigerants is very high pressure and does not need to be recovered?

Co2 refrigerant R-744 (Carbon dioxide) is a very high-pressure refrigerant and generally does not need to be recovered.

How many access valves are needed to recover the refrigerant on a sealed system?

one access valve
Because there is sufficient pressure, you only need to have one access valve to recover refrigerant. For a system with an operating compressor and a completely restricted capillary tube, we would attach one access valve on the high side of the system.

Which refrigerant does not need to be recovered?

It is not mandatory to repair the leak on small appliances, but it is recommended to do so whenever possible. Co2 refrigerant R-744 (Carbon dioxide) is a very high-pressure refrigerant and generally does not need to be recovered.

When pressurizing a system with nitrogen it is required to have?

Type 1

Question Answer
On a system with an operating compressor,recovery equipment must be capable of recovery 90% or achieving 4 inches of vacuum
When pressurizing a system with nitrogen you should; Both charge through a pressure regulator and install a relief valve in the line downstream from the pressure regulator.

What should a technician do if the refrigerant in a…?

If the refrigerant in a recovery cylinder is suspected to be contaminated, a pressure reading of the cylinder should be taken and compared to a pressure temperature chart. Recovery cylinders are specifically designed to be refilled. Recovery cylinders have 2 ports, one liquid and one vapor.

How to check for air contamination in a refrigerant tank?

To check for air contamination, a shop technician should note the pressure on the refrigerant recovery and storage tanks to see if it exceeds the maximum allowable pressure for a given ambient temperature. If it does, there is air in the tank and the tank needs to be purged before the refrigerant can be used.

Which is an approved substance for new household refrigerant?

Which of the following is an approved substance refrigerant for NEW household refrigeratos, freezers, and conbination refrigeration/freezers? Nice work! You just studied 25 terms!

Which is not important to do before recharging any flammable hydrocarbon or HFO?

Which of the following is NOT important to do before recharging any flammable hydrocarbon or HFO refrigerant into a system? What are the characteristics of hydrofluoroolefins (HFO’s)?

Who must certify recovery equipment used during maintenance, service or repair of small appliances that use CFCs, HCFCs, and HFCs?

Why should the technician watch for signs of contamination in the oil when recovering refrigerant from a system that experienced a compressor burnout? The system will have to be flushed if contaminants are present. … A compressor burnout has occurred.

What should a technician do if the refrigerant in a recovery cylinder is suspected to be contaminated quizlet?

What should a technician do if the refrigerant in a recovery cylinder is suspected to be contaminated? Turn refrigerant in for reclamation.

What is the service procedure if the refrigerant recovery cylinder is suspected to be contaminated?

If the refrigerant in a recovery cylinder is suspected to be contaminated, a pressure reading of the cylinder should be taken and compared to a pressure/temperature chart. Recovery cylinders are specifically designed to be refilled. Recovery cylinders have 2 ports, one liquid and one vapor.

Which of the following is NOT a recommended safety practice when operating refrigerant recovery or recycling equipment? Wear safety glasses. Wear protective gloves.

When recovering refrigerant into a non pressurized container from a refrigerator?

Which of the following refrigerants is most commonly used as a replacement for R-12 in new household refrigerators? When recovering refrigerant into a non-pressurized container from a refrigerator with an inoperative compressor: it is necessary to heat and strike the compressor with a rubber mallet.

Moisture can be removed from a refrigeration system by applying a vacuum. POEs hold moisture more tightly than mineral oil. But in the case of R-134a, the refrigerant effectively competes with the ester lubricant in partitioning the water (i.e., the water moves from the lubricant to the refrigerant).

Which refrigerant is very high pressure and does not need to be recovered?

Co2 refrigerant R-744 (Carbon dioxide) is a very high-pressure refrigerant and generally does not need to be recovered.

Which condition requires accessing both the high and low side of the system for refrigerant recovery?

using the system dependent (passive) recovery process, which condition requires accessing both the high and low side of the system for refrigerant recovery? it is necessary to heat the compressor and strike it with a rubber mallet.

How many access valves are needed to recover the refrigerant on a sealed system?

How many access valves do we need to recover refrigerant on a system that is sealed? We only need one access valve.

Where must you connect a hose in order to recover liquid refrigerant?

You need to connect a hose from the low side of the manifold to the high side of the recovery unit.

Which of the following is true if a system will not hold a vacuum after it has been evacuated?

Which of the following is TRUE if a system WILL NOT hold a vacuum after it has been evacuated? The system is ready to be charged.

Which refrigerant is not allowed to be vented?

Section 608 prohibits individuals from intentionally venting ODS refrigerants (including CFCs and HCFCs) and their substitutes (such as HFCs), while maintaining, servicing, repairing, or disposing of air- conditioning or refrigeration equipment.

When two or more refrigerants are mixed what must be done with the mixture?

If we mix two or more refrigerants with each other, We must keep it in a closed container to avoid the quick vaporization and we also have to take safety measures to avoid the toxic hazards of the mixture.

When recovering refrigerant from small appliances you must recover?

  • 80 percent of the refrigerant when. The technician uses recovery or recycling equipment manufactured before November 15, 1993, or. …
  • 90 percent of the refrigerant when.

Refrigerant should be removed from the condenser outlet if the condenser is below the receiver. In a building that has an air-cooled condenser on the roof and an evaporator on the first floor, recovery should begin from the liquid line entering the evaporator.

Which of the following repairs would always be considered major under EPA’s regulations?

the system water pumps, the recovery compressor, and the recovery condenser water should all be on. Which of the following repairs would ALWAYS be considered “major” under EPA’s regulations? Replacement of an evaporator coil.